Click image to view full size image
Product: Views:2Patient Monitor CE Approved 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2017-02-14 21:12
  Inquiry
Details

Basic Info.
  • Model No.: CMS7000 
  • Place of Origin: Hebei  
Supply Capacity
  • Packing:carton
  • Delivery Date: in five days after receipt of payment
Multi-parameter patient monitor is the one of high price/ performance ratio, high security and low consumption of power. In order to insure the quality and reduce the risk may occur in the operation process, it adopts the technology of full isolation floating, ECG anti-defibrillation protection, ECG Anti-high-frequency interference, and NIBP Dual Over Pressure protection to prevent the damage caused by single problem. It makes this product safe and efficient.

Feature
| 12.1"High bright TFT LCD display | Portable, streamline handle design | Big figure display   | ECG Waveforms of 7-lead displayed in one screen | 96-hour tabular and graphic trends & date storage | Compatible and self identify 3-lead and 5-lead ECG cable | NIBP dual Over Pressure Protection | Isolated floating, anti defibrillation protected and anti high-frequency interference | Networking capacity NIBP: | Method: Oscillometry | Modes: Manual/Auto/Continuous | Auto measure time: Adjustable | Measurement rang: 10-270mmHg ECG: | Lead mode: 3-lead or 5-lead | Lead selection: I, II, III, avR, avL, avF, V | Heart rate range: Adult: 15-300bpm,   Pediatric/Neonatal: 15-300bpm | ECG waveform: 2 channels | Accuracy: ± 1 bpm or ±1% | S-T segment detection Measurement range:-0.2mv~2.0mv | Alarm: Yes, audible and visual alarm, alarm events review SPO2 | Measurement range: 0-100% | Accuracy: 70-100%, ±2% 0-69%,upspecified Pulse rate | Range: 20-254bpm | Accuracy: ±3bpm Respiration | Method: RA-LL impedance | Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm | Apnca alarm: Yes Temperature Range: 0-50℃ | Apnca: 0.1℃ | Channel: Dual-Channel Standard parameter & configuration | 3/5 lead ECG, RESP, SpO2, NIMP, TEMP, PR, Network Optional parameter & configuration | 2-IBP, Recorder,12 lead ECG, ETCO2
Option: EtCO2

Measurement Mode: Side-stream or mainstream
Measurement range: EtCO2: 0-99mmHg Accuracy: CO2 concentration Apnea alarm: YES
IBP

Channel: 2 channels
Pressure transducer: Sensitivity: 5( mV/V/mmHg) Transducer sites: ART, PA, CVP, RAP, LAP, ICP Alarm range: -10~300mmHg